PRODUCT DISPLAY


Location:Home - PRODUCTS - Power Cable


PVC Insulated Power Cables for Coal Mines with Rated Voltage 1.8/3kV and Below (MVV, MVV22)

prev
next
  • PRODUCT DETAILS

I.Product Uses and Characteristics
  Rated Voltage1.8/3kV and below coal mine PVC insulated power cables, is a safety-type cable designed specifically for fixed laying conditions in underground coal mines. Its core value lies in its flame-retardant and durable properties, ensuring that in harsh and high-risk underground environments, it can provide continuous, stable, and safe power supply for various key equipment, making it an indispensable infrastructure for ensuring safe coal mine production.
II. Product Standards
MT818.12--2009
III. Product Modelsand Names

Model   No.

Name      Designation

MVV

Coal mine PVC insulated PVC sheathed power cable

MVV22

Coal mine PVC insulated steel tape armored PVC sheathed power cable

Table1

IV.Product Specifications

Model   No.

Core  Count

Rated  Fixed  Electric  Voltage   kV

0.6/1

1.8/3

Nominal  Designation  Cross  Section

mm2

MVV

3

1.5~300

10~300

MVV22

3

2.5~300

10~300

MVV

3 + 1

4~300

10~300

MVV22

3 + 1

4~300

10~300

MVV

4

4~185

4~185

MVV22

4

4~185

4~185

                           Table2

V. Technical Requirements

5.1 Conductor

  The composition, performance, and appearance of the conductor shall comply withthe provisions of 5.1 in MT 818.11-200x.

5.2 Insulation

5.2.1 The insulation shall use PVC/A material, and its performance shall comply with the provisions of Table 14 and Table 16 of MT 818.11.

5.2.2 The thickness of the insulation shall comply with the provisions of 5.2.2 of MT 818.11-200x and Table 3 of this part.

Table 3 Nominal insulation thickness

Nominal conductor

Cross    Section

mm2

Rated voltage

 kV

Nominal conductor

Cross    Section

mm2

Rated voltage  

kV

0.6/1

1.8/3

0.6/1

1.8/3

Nominal insulation thickness

 mm

Nominal insulation thickness  

mm

1.5

0.8

—

50

1.4

2.2

2.5

0.8

—

70

1.4

2.2

4

1.0

—

95

1.6

2.2

6

1.0

—

120

1.6

2.2

10

1.0

2.2

150

1.8

2.2

16

1.0

2.2

185

2.0

2.2

25

1.2

2.2

240

2.2

2.2

35

1.2

2.2

300

2.4

2.4

5.2.3 The cross-section of the insulation layer shall be free of visible defects such as bubbles and sand holes to the naked eye.

5.3 Shielding

Cables with a rated voltage U0/U of 1.8/3kV shall have metallic shielding. The metallic shielding shall consist of copper tapes applied separately per phase or collectively wrapped, with a nominal thickness of 0.10mm, and its average thickness shall not be less than 90% of the specified nominal value.

5.4 Cable core and inner covering

The cable core and inner covering shall comply with the provisions of 5.4 of MT 818.11-2009.

5.5 Armor

The cable armor shall comply with the provisions of 5.5 of MT 818.11-200x.

5.6 Non-metallic sheath

The sheath shall be of ST1 type, and its thickness shall comply with the provisions of 5.6 of MT 818.11-200x; the sheath performance shall comply with the provisions of Table 15 and Table 16 of MT 818.11-200x.

5.7 Operating conditions

5.7.1 The maximum rated operating temperature of the cable conductor is 70℃.

5.7.2 During short circuit (with a maximum duration not exceeding 5s), the maximum temperature of the cable conductor shall not exceed 160℃.

5.7.3 The ambient temperature when laying the cable shall not be lower than 0℃, and the minimum bending radius shall be 15 times the cable diameter.

6 Test methods and inspection rules

The cable shall be tested according to the provisions of Table 4 to check whether it meets the corresponding requirements. The inspection rules shall comply with the provisions of Chapter 6 of MT 818.11-200x.

Table 4 Test items

Serial number

Item name

Test requirements

Test type

Test method

Standard number

Clause number

0.6/1kV

1.8/3kV

1

Conductor DC resistance

MT 818.11

6.2.1

R

R

GB/T 3048.4

2

AC voltage test

MT 818.11

6.2.3

R

R

GB/T 3048.8

3

Structure and dimension inspection






3.1

Conductor structure

MT 818.11

6.3.2.1

S

S

Visual inspection

3.2

Insulation thickness

MT 818.11

6.3.2.2

S

S

GB/T 2951.1

3.3

Armor

MT 818.11

6.3.2.3

S

S

GB/T 2951.1

3.4

Sheath thickness

MT 818.11

6.3.2.4

S

S

GB/T 2951.1

4

Flame retardant performance test






4.1

Single vertical burning test

MT 818.11

6.3.5

S

S

MT 386

4.2

Burning test under load conditions

MT 818.11

6.3.5

S

S

MT 386

5

Structure and dimension inspection






5.1

Insulation thickness

MT 818.11

6.4.6.1

T

T

GB/T 2951.1

5.2

Sheath thickness

MT 818.11

6.4.6.2

T

T

GB/T 2951.1

6

Insulation resistance test






6.1

Test at room temperature

MT 818.11

6.4.2.3.2

T

T

GB/T 3048.5

6.2

Test at maximum rated operating temperature

MT 818.11

6.4.2.3.3

T

T

GB/T 3048.5

7

4h AC voltage test

MT 818.11

6.4.2.4

T

T

GB/T 3048.8

8

Impulse voltage test

MT 818.11

6.4.2.5

—

T

GB/T 3048.13

9

Conductor DC resistance

MT 818.11

6.4.2.6

T

T

GB/T 3048.4

10

Insulation mechanical and physical properties test






10.1

Mechanical properties test before aging

MT 818.11

6.4.3.1

T

T

GB/T 2951.1

10.2

Mechanical properties test after aging

MT 818.11

6.4.3.1

T

T

GB/T 2951.2

11

Sheath mechanical and physical properties test






11.1

Mechanical properties test before aging

MT 818.11

6.4.3.2

T

T

GB/T 2951.1

11.2

Mechanical properties test after aging

MT 818.11

6.4.3.2

T

T

GB/T 2951.2

12

Additional aging test for finished cable segments

MT 818.11

6.4.3.3

T

T

6.4.3.3 in MT 818.11

13

High temperature pressure test for PVC insulation and sheath

MT 818.11

6.4.3.5

T

T

GB/T 2951.6

14

Low temperature performance test for PVC insulation and sheath

MT 818.11

6.4.3.6

T

T

GB/T 2951.4

15

Crack resistance of PVC insulation and sheath(thermal shock) test

MT 818.11

6.4.3.7

T

T

GB/T 2951.6

16

Water absorption test for PVC insulation

MT 818.11

6.4.3.8

T

T

GB/T 2951.3

17

Special bending test

MT 818.11

6.4.3.12

T

T

6.4.3.12 in MT 818.11

18

Printed mark rub resistance test

MT 818.11

6.4.4

T

T

GB 6995


                                   Table 4 (continued)Test items

Serial number

Item name

Test requirements

Test type

Test method

Standard number

Clause number

0.6/1kV

1.8/3kV

19

Flame retardant performance test






19.1

Single vertical burning test

MT 818.11

6.4.5

T

T

MT 386

19.2

Burning test under load conditions

MT 818.11

6.4.5

T

T

MT 386

19.3

Bunched burning test

MT 818.11

6.4.5

T

T

MT 386

1)Item 17 only applies to cables with structures specified in 5.4.3 of MT 818.11


INQUIRY