PRODUCT DISPLAY

Leaky Coaxial Cables for Coal Mines (MSLYFVZ, MSLYFYVZ)

prev
next
  • PRODUCT DETAILS

1. Product Purpose and Features
  Mine leaky coaxial cables are mainly applied to underground wireless communication systems, precise positioning systems for personnel and equipment, locomotive transportation monitoring systems, emergency communication and rescue. It is a special type of cable integrating the functions of "transmission line" and "antenna", and meets the extreme safety requirements for underground coal mines.

2. Product Standards
GB/T2951-2008
3. Product Models and Names

Serial No.

Name

Model

Specification

1

Mine Leaky Coaxial Cable

MSLYFVZ

50-9

2

Mine Leaky Coaxial Cable

MSLYFVZ

75-9

3

Mine Leaky Coaxial Cable

MSLYFYVZ

50-9

4

Mine Leaky Coaxial Cable

MSLYFYVZ

75-9

Table1

4.Product Specifications

 

Model

Inner Conductor

Insulation

Outer Conductor

Sheath

Material

Diameter mm

Material

Diameter

mm

Material

Diameter

mm

Material

Diameter

mm

MSLYFYVZ-50-9

 

 

Copper or

Copper-clad

Aluminum

3.5±0.05

 

Physically

Foamed

Polyethylene

Insulation

 

 

 

8.8  ±0.2

 

Braided or stranded copper wire(Braiding density 40~   55%)

 

 

 

≤9.8

Low DensityPolyethylene+Flame RetardantPVC

≤13.7

MSLYFYVZ-75-9

2.0±0.03

≤13.7

MSLYFVZ-50-9

3.5±0.05

Flame Retardant PVC

≤12.6

MSLYFVZ-75-9

2.0±0.03

≤12.6

                             Table2
5. Technical Requirements

5.1 Environmental and Mechanical Properties

5.1.1 Low Temperature Test

  Test temperature: -40±3°C, test bending radius: 250mm.

Table3 Mechanical Properties of Insulation and Sheath

 

No.

Test Item

Technical Requirements

PE Inner Sheath

PVC Sheath

1

Mechanical Properties Before Aging



1.1

Tensile Strength (N/mm2)

≥10

≥12.5

1.2

Elongation at Break (%)

≥350

≥150

2

Thermal Aging Test



2.1

Test Temperature (°C)

90±2

100±2

2.2

Test Duration (h)

4×24

7×24

2.3

Tensile Strength (N/mm2)

—

≥12.5

2.4

Elongation at Break (%)

—

≥150

2.5

Variation Rate of Elongation at Break (%)

≥-35

Not exceeding ±25

 5.1.2 Flame Retardant Test

  The flame retardant performance of the cable shall comply with the test requirements specified in Clause 5.4.2 of GB43069-2023.

5.1.3 The lead and arsenic content of cable materials shall meet the requirements of Clause 5.5.1 of GB43069-2023.

5.2 Electrical Properties

5.2.1 Conductor Continuity Test

  No short circuit or open circuit shall occur between inner and outer conductors.

5.2.2 DC Resistance of Inner Conductor

  The DC resistance of inner conductor shall conform to the requirements in Table 4.

                   Table4  DC Resistance of Inner Conductor at 20℃

 

Item

Material

MSLYF(Y)VZ-50-9

MSLYF(Y)VZ-75-9

DC Resistance of Inner Conductor

20℃, max Ω/km

 

Copper Wire

 

1.8

 

6.0

5.2.3 Insulation Resistance

  The insulation resistance of finished cable at 20℃ shall be no less than 1000MΩ·km.

5.2.4 Dielectric Strength of Insulation

  The finished cable shall withstand power frequency voltage withstand test of 1.5kV (r.m.s.) for 1min without breakdown.

5.2.5 Characteristic Impedance

  Characteristic impedance is shown in Table 5.

Table5 Characteristic Impedance

 

No.

Model & Specification

Characteristic Impedance(Ω)

1

MSLYF(Y)VZ-50-9

50±3

2

MSLYF(Y)VZ-75-9

75±3

5.2.6衰减常数

衰减常数应符合表6要求。

5.2.7耦合损耗

耦合损耗应符合表6要求。

表6衰减常数和耦合损耗

 

序号

型号规格

衰减常数(dB/km)

耦合损耗(dB)

60MHz

150MHz

450MHz

60MHz

150MHz

450MHz

1

MSLYF(Y)VZ-50-9

≤40

≤60

≤100

85±10

75±10

75±10

2

MSLYF(Y)VZ-75-9

≤40

≤55

≤100

80±10

80±10

75±10

5.2.8 Voltage Standing Wave Ratio

  The voltage standing wave ratio of the cable within the frequency band of 60MHz~450MHz shall not be greater than 1.3.4.4

5.3 Delivery Length

  The standard delivery length of cables shall be an integer multiple of 100m or 200m. Subject to the agreement between the supplier and purchaser, any length is acceptable for delivery. The tolerance of length marking shall not exceed ±1.0%.

6 Test Methods and Acceptance Rules

6.1 Factory Delivery Requirements

  All cables shall be inspected by the manufacturer’s quality inspection department and can only be delivered after passing inspection. Each delivered cable shall be accompanied by a quality inspection certificate.

6.2 Product Inspection

  Cable inspections are classified into Type Test (T), Routine Test (R) and Sampling Test (S). Inspection items, test types and test methods shall be implemented in accordance with Table 7.

Table 7 Test Methods and Inspection Rules

 

No.

Item Name

Technical Requirement

Clause No.

Test Type

Test Method (Standard No.)

1

Structural Dimensions

This Standard

4.1.1

T、S

GB/T15285

2

Mechanical Properties of Insulation and Sheath

This Standard


T

GB/T2951

3

Electrical Properties

This Standard




3.1

DC Resistance of Inner Conductor

This Standard

4.3.2

T、R

GB/T17737.1

3.2

Insulation Resistance

This Standard

4.3.3

T、R

GB/T15285

3.3

Dielectric Strength of Insulation

This Standard

4.3.4

T、R

GB/T15285

3.4

Characteristic Impedance

This Standard

4.3.5

T、S

GB/T17737.1

3.5

Attenuation Constant

This Standard

4.3.6

T、S

GB/T15285

3.6

Coupling Loss

This Standard

4.3.7

T、S

GB/T15285

3.7

Voltage Standing Wave Ratio

This Standard

4.3.8

T、S

GB/T15285

4

Low Temperature Performance

This Standard

4.2.1

T

GB/T17737.1

5

Flame Retardant Performance





Single Vertical Flame Test

This Standard

4.2.2

T,S

GB43069-2023

6

Lead and Arsenic Content of Cable Materials

This Standard

4.2.3

T

GB43069-2023

7

Appearance and Marking

This Standard

6

T、S

Visual Inspection

6 Packaging, Marking, Transportation and Storage

6.1 Packaging

  Cable delivery drums shall comply with the provisions of JB/T8137. Cables shall be delivered in coils or on drums, and both ends of each cable shall be sealed. Cables delivered in coils shall be neatly bundled and packed; for cables delivered on drums, the distance between the outermost layer of cable and the outer edge of the delivery drum shall not be less than 20mm.

6.2 Packaging Markings

  Each coil or drum of cable shall be attached with a label indicating the following contents:

1) Name of manufacturer;

2) Product model and specification;

3) Length (m);

4) Manufacturing date or production batch number;

5) Number of this standard;

6) Safety mark identification.

6.3 Transportation and Storage

Precautions shall be taken during cable transportation and storage: prevent water and moisture from invading the cable; avoid high temperature and open flames; avoid severe bending and extrusion deformation; prevent any mechanical damage.

INQUIRY

If you are interested in our products, or want to ask related questions, please leave a message to us.

We will reply and serve you as soon as possible. Thank you for visiting our official website.